3Com 3CRUS2475 User Manual page 296

Unified gigabit wireless poe switch 24
Hide thumbs Also See for 3CRUS2475:
Table of Contents

Advertisement

296
C
15: V
HAPTER
IEWING
S
TATISTICS
To modify Alarm Settings:
1 Click Wired Ports > Stats > RMON Alarms > Modify Alarm. The
RMON Alarms Modify Alarm Page opens:
Figure 154 RMON Alarms Modify Alarm Page
The RMON Alarms Modify Alarm Page contains the following fields:
Alarm Entry — Indicates a specific alarm.
Interface — Displays interface for which RMON statistics are
displayed. The possible field values are:
Port — Displays the RMON statistics for the selected port.
LAG — Displays the RMON statistics for the selected LAG.
Counter Name — Displays the selected MIB variable.
Counter Value — Displays the selected MIB variable value.
Sample Type — Defines the sampling method for the selected
variable and comparing the value against the thresholds. The possible
field values are:
Delta — Subtracts the last sampled value from the current value.
The difference in the values is compared to the threshold.