Tuning Parameters: C

Acceleration/Deceleration: C1
Name
Param-
eter
Num-
Display
ber
Acceleration time 1 Sets the acceleration time to
C1-01
Accel Time 1
Deceleration time 1 Sets the deceleration time to
C1-02
Decel Time 1
Acceleration time 2 Sets the acceleration time when
C1-03
Accel Time 2
Deceleration time 2 Sets the deceleration time when
C1-04
Decel Time 2
Acceleration time 3 Sets the acceleration time when
C1-05
Accel Time 3
Deceleration time 3 Sets the deceleration time when
5
C1-06
Decel Time 3
Acceleration time 4 Sets the acceleration time when
C1-07
Accel Time 4
Deceleration time 4 Sets the deceleration time when
C1-08
Decel Time 4
Emergency stop
time
C1-09
Fast Stop Time
Accel/decel time
setting unit
C1-10
Acc/Dec Units
Decel time switch-
ing frequency
C1-11
Acc/Dec SW Freq
*1. The setting range for acceleration/deceleration times depends on the setting of C1-10. If C1-10 is set to 1, the setting range for acceleration/deceleration
times becomes 0.0 to 6000.0 seconds.
12
5-
Setting
Description
Range
accelerate from 0 Hz to the
maximum output frequency.
decelerate from the maximum
output frequency to 0 Hz.
the multi-function input "accel/
decel time 1" is set to ON.
the multi-function input "accel/
decel time 1" is set to ON.
0.00 to
the multi-function input "accel/
600.00
decel time 2" is set to ON.
the multi-function input "accel/
decel time 2" is set to ON.
the frequency reference is
below the value set in C1-11.
the frequency reference is
below the value set in C1-11.
Sets the deceleration time when
the frequency reference is
below the value set in C1-11.
Sets the number of decimals for
the acceleration / deceleration
time parameters.
0: 0.01-second units
1: 0.1-second units
Sets the frequency for automatic
acceleration/deceleration
switching.
If the output frequency is below
the set frequency: Accel/decel
time 4
If the output frequency is above
the set frequency: Accel/decel
time 1.
Change
Factory
during
Setting
Opera-
V/f
tion
Yes
Q
Yes
Q
Yes
A
Yes
A
Yes
A
1.50 s
*1
No
A
No
A
No
A
No
A
0 or 1
0
No
A
0.0 to
0.0 Hz
No
A
120.0
0.0 to
0.0 %
No
-
100.0
Control Methods
MEMO-
Closed
Open
Closed
BUS
Loop
Loop
Loop
Register
Vector
Vector
Vector
(PM)
Q
Q
Q
200H
Q
Q
Q
201H
A
A
A
202H
A
A
A
203H
A
A
A
204H
A
A
A
205H
A
A
A
206H
A
A
A
207H
A
A
A
208H
A
A
A
209H
A
A
-
20AH
-
-
A
Page
6-20
6-20
6-20
6-20
6-20
6-20
6-20
6-20
6-10
-
6-20
6-21