Simple Short Floor Operation Setup
The short floor function can be activated by setting parameter S3-01 to 1.
If parameter d1-18 is set to 0 or 3 (multispeed input), the set value of parameter S3-05 is taken as nominal
speed reference for the short floor calculation. Additionally it is required to use the nominal/leveling speed
detection (refer to
If parameter d1-18 is set to 1 or 2 (dedicated speed inputs), the value of parameter d1-09 is taken as nomi-
nal speed. The set value of S3-05 has no meaning. The nominal/leveling speed detection must not be used.
Advanced Short Floor Operation Setup
The advanced short floor operation can be activated by setting parameter S3-01 to 2.
If parameter d1-18 is set to 0 or 3 (multispeed input), the speed reference value, which was selected at the
start, is taken as nominal speed for the speed pattern calculation. Parameter S3-04 is used for the leveling
speed detection (refer to
If parameter d1-18 is set to 1 or 2 (dedicated speed input), the value of parameter d1-09 is taken as nominal
speed for the speed pattern calculation.
18
6-
Standard Short Floor
Leveling command during run with constant speed
higher than 40%
f
out
Leveling
command
Leveling command during run with constant speed
lower than 40%
f
out
Leveling
command
Name
Nominal Speed
Speed reference priority selection
Short floor operation
Nominal / Leveling Speed detection level
Nominal speed for short floor calculation
Minimum constant speed time
Distance calculation acceleration time gain
Distance calculation deceleration time gain
page 6-6, Nominal / Leveling Speed Detection with Multi Speed
page
-6).
Advanced Short Floor
v
Nominal
40% x
V
Nominal
V
Leveling
No effect
v
Nominal
40% x
V
Nominal
V
Leveling
Change
Factory
during
Setting
V/f
Operation
50.00 Hz
Q
No
100.00%
-
1
No
A
0
No
A
0.0 Hz
No
A
0.0Hz
No
A
0.0 sec.
No
A
150.0%
No
A
150.0%
No
A
Control Methods
Closed
Open
Closed
Loop
Loop
Loop
Vector
Vector
Vector
(PM)
Q
Q
-
-
-
Q
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Inputs).

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents