Fault Detection

Related Parameters
Parameter
No.
F1-02
F1-03
F1-04
F1-08
F1-09
F1-10
F1-11
F1-14
F1-18
F1-19
F1-21
F1-22
F1-24
Detecting PG Open Circuit During Run (F1-02 and F1-14)
Parameter F1-02 selects the stopping method when a PG disconnection is detected.
6
PG open (PGO) is detected only when the inverter is running at least with a frequency reference higher than
1% of the maximum output frequency or above the minimum frequency (E1-09) and the PG feedback signal is
missing for the time set in F1-14 or longer.
Detecting Motor Overspeed (F1-03, F1-08 and F1-09)
An overspeed (OS) is detected when the motor speed continues to exceed the set frequency value in F1-08 for
a time longer than set in F1-09. After detecting an overspeed (OS), the Inverter stops according to the setting
in F1-03.
Detecting a Speed Deviation between the Motor and Speed Reference (F1-04, F1-10
and F1-11)
A speed deviation fault is detected when the speed deviation (i.e., the difference between the speed reference
and the actual motor speed) is too large. Speed deviation (DEV) is detected only after a speed agreement
(speed reference and actual motor speed are within the setting range of L4-02) and if a speed deviation higher
than the set value in F1-10 continues for longer than the time set in F1-11. After a speed deviation is detected,
the Inverter stops according to the setting in F1-04.
Detecting a Wrong Rotation Direction DV3 (F1-18, Closed Loop Vector for PM only)
A DV3 fault indicates a wrong motor rotation direction. It is detected if
the speed deviation is higher than 30% and
the internal torque reference value and the acceleration have opposite signs
The fault is detected after the time F1-18 x 5 ms.
74
6-
Name
Operation selection at PG open circuit (PGO)
Operation selection at overspeed (OS)
Operation selection at deviation (DEV)
Overspeed detection level
Overspeed detection time
Speed deviation detection level
Speed deviation detection time
PG open-circuit detection delay time
DV3 detection selection
DV4 detection selection
Absolute encoder resolution
Magnet position offset
PGO detection Level at stop
Control Methods
Change
Factory
during
Open
Setting
Opera-
V/f
Loop
tion
Vector
1
No
-
1
No
-
3
No
-
115%
No
-
0.0 sec.
No
-
10%
No
-
0.5 sec.
No
-
2.0 s
No
-
1
No
-
1024
No
-
2
No
-
60°
No
-
20%
No
-
Closed
Closed
Loop
Loop
Vector
Vector
(PM)
-
A
A
-
A
A
-
A
A
-
A
A
-
A
A
-
A
A
-
A
A
-
A
A
-
-
A
-
-
A
-
-
A
-
-
A
-
-
A

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents