Omron VARISPEED L7 Manual page 278

Hide thumbs Also See for VARISPEED L7:
Table of Contents

Advertisement

Table 9.3 Common Specifications
Model Number
Specification
CIMR-L7Z
Enclosed wall-mounted type (IP20): All models
Protective structure
Enclosed wall-mounted type (NEMA 1): 18.5 kW or less (same for 200 V and 400 V class Inverters)
Open chassis type (IP00): 22 kW or more (same for 200 V and 400 V class Inverters)
Ambient operating tem-
-–10°C to 45°C, max. 60°C with derating (refer to
page 9-6, Ambient Temperature
Derating)
perature
Ambient operating
95% max. (with no condensation)
humidity
Storage temperature
- 20°C to + 60°C (short-term temperature during transportation)
Application site
Indoor (no corrosive gas, dust, etc.)
Altitude
1000 m, max. 3000 m with derating (refer to
page 9-7, Altitude
Derating).
2
2
Vibration
10 to 20 Hz, 9.8 m/s
max.; 20 to 50 Hz, 2 m/s
max
Hardware Baseblock meets EN954-1 safety category 3, stop category 0
Safe Disable
EN81-1 conform one motor contactor solution possible
Harmonics
EN 12015 can be fulfilled with optiona AC reactor
9
5
9-

Hide quick links: