Omron VARISPEED L7 Manual page 220

Hide thumbs Also See for VARISPEED L7:
Table of Contents

Advertisement

Comparing Inverter Parameters and Digital Operator Parameter Set Values (VERIFY)
To compare Inverter parameters and Digital Operator parameter set values, use the following method.
Step
No.
1
Press the MENU Key and select advanced programming mode.
2
Press the DATA/ENTER Key.
Press the Increment and Decrement Key until the parameter o3-01 is displayed (Copy Func-
3
tion Selection).
4
Press the DATA/ENTER Key and select the function setting display.
5
Change the set value to 3 using the Increment Key.
6
Set the changed data using the DATA/ENTER Key. The VERIFY function starts.
7
If the VERIFY function ends normally, "End" is displayed on the Digital Operator.
8
The display returns to o3-01 when a key is pressed.
If an error is displayed, press any key to cancel the error display and return to the o3-01 display. Refer to
page 7-16, Digital Operator Copy Function Faults
Application Precautions
When using the copy function, check that the following settings are the same between the Inverter data and the
Digital
• Inverter product and type
INFO
• Software number
• Inverter capacity and voltage class
• Control method
Explanation
for corrective actions.
Digital Operator Display
-ADV-
** Main Menu **
Programming
-ADV-
Initialization
A1
- 00 = 1
Select Language
-ADV-
COPY Function
o3
- 01=0
Copy Funtion Sel
-ADV-
Copy Function Sel
o3-01=
0
*0*
COPY SELECT
-ADV-
Copy Funtion Sel
o3-01=
3
*0*
OP
INV VERIFY
-ADV-
VERIFY
DATA VERIFYING
-ADV-
VERIFY
VERIFY COMPLETE
-ADV-
Copy Function Sel
o3 -
01
= 0
*0*
COPY SELECT
6
69
6-

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading