Tuning Parameters: C

Acceleration/Deceleration: C1
Param-
Name
eter
Num-
Display
ber
Acceleration
time 1
C1-01
Accel Time 1
Deceleration
time 1
C1-02
Decel Time 1
Acceleration
time 2
C1-03
Accel Time 2
Deceleration
time 2
C1-04
Decel Time 2
Acceleration
time 3
C1-05
Accel Time 3
Deceleration
5
time 3
C1-06
Decel Time 3
Acceleration
time 4
C1-07
Accel Time 4
Deceleration
time 4
C1-08
Decel Time 4
Fast stop
time
C1-09
Fast Stop
Time
Accel/decel
time setting
unit
C1-10
Acc/Dec
Units
Accel/decel
time switch-
ing fre-
quency
C1-11
Acc/Dec SW
Freq
* 1. The setting range for acceleration/deceleration times will depends on the setting for C1-10. When C1-10 is set to 0, the setting range for acceler-
ation/deceleration times becomes 0.00 to 600.00 seconds.
* 2. The given setting range is valid if Heavy Duty is selected (C6-01=0, default setting). If Normal Duty 1 or 2 is selected (C6-01=1 or 2) the setting
range will be 0.0 to 400.0 Hz
20
5-
Setting
Description
Range
Sets the acceleration time to
accelerate from 0 Hz to the
maximum output frequency.
Sets the deceleration time to
decelerate from the maximum
output frequency to 0 Hz.
Sets the acceleration time when
the multi-function input "accel/
decel time 1" is set to ON.
Sets the deceleration time when
the multi-function input "accel/
decel time 1" is set to ON.
Sets the acceleration time when
the multi-function input "accel/
0.0 to
decel time 2" is set to ON.
6000.0
Sets the deceleration time when
the multi-function input "accel/
decel time 2" is set to ON.
Sets the acceleration time when
the multi-function input "accel/
decel time 1" and "accel/decel
time 2" are set to ON.
Sets the deceleration time when
the multi-function input "accel/
decel time 1" and "accel/decel
time 2" are set to ON.
Sets the deceleration time when
the multi-function input "Fast
Stop" is set to ON.
0: 0.01-second units
0 or 1
1: 0.1-second units
Sets the frequency for auto-
matic acceleration/decelera-
tion switching.
If the output frequency is
below the set frequency: Accel/
0.0 to
decel time 4
150.0
If the output frequency is above
the set frequency: Accel/decel
time 1
The multi-function input
"accel/decel time 1" or "accel/
decel time 2" has priority.
Control Methods
Change
Factory
during
Setting
Opera-
V/f
tion
Yes
Q
Yes
Q
Yes
A
Yes
A
No
A
10.0 s
* 1
No
A
No
A
No
A
No
A
1
No
A
0.0 Hz
No
A
* 2
MEMO-
V/f
Open
Closed
BUS
with
Loop
Loop
Register
PG
Vector
Vector
Q
Q
Q
200H
Q
Q
Q
201H
A
A
A
202H
A
A
A
203H
A
A
A
204H
A
A
A
205H
A
A
A
206H
A
A
A
207H
A
A
A
208H
A
A
A
209H
A
A
A
20AH
Page
4-5
6-20
4-5
6-20
6-20
6-20
6-20
6-20
6-20
6-20
6-20
6-20
6-20