During Regenerative Operation (Setting: 1D)
If a multifunction output is set to this function, the output is switched ON when the motor works regenerative,
i.e. when energy is fed back to the inverter.
Restart Enabled (Setting: 1E)
Refer to
page 6-81, Automatic Fault
During Torque Limit (Setting: 30)
Refer to
page 6-43, Limiting the Motor Torque (Torque Limit
Zero Servo End (Setting: 33)
Refer to
page 6-16, Zero Speed Control / Zero Servo (position
Brake Release Command (Setting: 40)
This output signal can be used to control the brake. The output is closed when the brake shall be opened. Refer
also to
page 6-13, Brake
Motor Contactor Control Command (Setting: 41)
This output can be used to control the motor contactors. The output is closed when the contactors shall be
closed. Refer also to
Cooling Fan Running (Setting: 38)
This output can be used to indicate the inverters heatsink cooling fan operation. The output is on if the cooling
fan(s) is (are) on.
6
Speed Detection at deceleration (Door Zone) (Setting:42)
This output can be used to detect if the car is in the door zone. The detection is speed dependent.
OFF
ON
If the Up/Down command is released, this output is switched OFF.
Not Zero Speed (Setting:43)
This function can be used for indicating the inverse condition of the Zero speed status.
OFF
ON
Light Load Search End (Setting: 44/45)
Refer to
page 6-80, Light Load Direction
Base Block Monitor 1 and 2 (Setting: 46/47)
If a multifunction output is programmed for this function, the output is switched if both base block inputs (BB
and BB1) are enabled.
58
6-
Reset.
Sequence.
page 6-13, Brake
Sequence.
V/f control and Open Loop Vector control
The output frequency is lower than S1-27 during
deceleration
The output frequency is higher than S1-27 during
deceleration
The output frequency is lower than the zero speed level.
The output frequency is higher than the zero speed level.
Detection.
Function).
lock).
Closed Loop Vector control
The motor speed is lower than S1-27 during deceler-
ation
The motor speed is higher than S1-27 during deceler-
ation