Omron NE1A-SCPU01 - 2006 Operation Manual page 238

Safety network controller
Table of Contents

Advertisement

Indicator/Display Status and Corrective Actions for Errors
Indicators/display
NS
Seven-
segment
display
L9
Master node
address
Flashing
red
dA
Desti-
nation slave
node
Flashing
address
red
d5
Desti-
nation slave
node
Flashing
address
red
d6
Desti-
nation slave
node
Flashing
address
red
d6
Desti-
nation slave
node
Flashing
address
red
E0
Node
OFF
address of
error
---
E2
Node
address of
error
A0
Node
address of
Flashing
error
red
A1
Node
address of
Flashing
error
red
Error history
I/O
Name
---
Standard I/O
Connection
Timeout
---
Safety I/O
Connection
Timeout
---
Nonexistent Slave
Device
---
Safety I/O
Connection
Establishment Fail-
ure
---
Invalid Slave
Device
---
Network PS
Voltage Low
---
Transmission
Timeout
---
Relevant Safety I/O
communication
stopped because of
a Safety I/O
communication
error
---
All Safety I/O
com-munication
stopped because
ofa Safety I/O
communication
error
Cause
Saved in
nonvola-
tile
memory
See note
Standard I/O
1.
connection
timeout
See note
Safety I/O
1.
connection
timeout
See note
No slave
1.
See note
Safety I/O con-
1.
nection establish-
ment error
See note
Invalid slave
1.
device (verifica-
tion error)
See note
Network power
1.
supply voltage
low error
See note
Transmission
1.
timeout
Yes
A safety I/O
(See note
connection timed
2.)
out, interrupting
the relevant I/O
connection.
Yes
A safety I/O
(See note
connection timed
2.)
out, interrupting
the relevant I/O
connection.
Section 10-3
Corrective actions
Check the following points:
• Make sure the baud rate is the
same for all nodes.
• Make sure the cable lengths
(main/branch) are not too
long.
• Make sure the cable is not dis-
connected or loose.
• Make sure terminating resis-
tance is at both ends of the
main line and only at both
ends.
• Make sure that there is not a
lot of noise.
Check the slave device.
• Make sure it its configured.
• Make sure it is in a normal
operational state.
Verify the slave device (select
Device - Parameters - Com-
pare) and connect a suitable
slave device.
Check the following points:
• Make sure the power supply
voltage is set within the speci-
fied range.
• Make sure a cable or wire is
not disconnected.
Check the following points:
• Make sure the baud rate is the
same for all nodes.
• Make sure the cable lengths
(main/branch) are not too
long.
• Make sure the cable is not dis-
connected or loose.
• Make sure terminating resis-
tance is at both ends of the
main line and only at both
ends.
• Make sure that there is not a
lot of noise.
Check the following points:
• Make sure the baud rate is the
same for all nodes.
• Make sure the cable lengths
(main/branch) are not too
long.
• Make sure the cable is not dis-
connected or loose.
• Make sure terminating resis-
tance is at both ends of the
main line and only at both
ends.
• Make sure that there is not a
lot of noise.
203

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ne1a-scpu02 - 2006Ne1a-scpu01Ne1a-scpu01-v1Ne1a-scpu02

Table of Contents