Command Reference: Function Blocks

6-5

Command Reference: Function Blocks

6-5-1

Function Block: Reset

Diagram
General Description
Conditions for Output Enable Turning ON
Conditions for Static Release Turning ON
Conditions for Reset Required Indication Turning ON
Set Parameters
Parameter
Reset Signal
Number of Inputs Setting
Parameter
Number of inputs
Reset
Monitored Input
Default Connections
The Output Enable signal will turn ON if the Reset signal is correctly input
while the input condition to the Reset function block is ON.
This function block can be used to prevent the machine from automatically
reset, e.g., when the power to the NE1A-series Controller is turned ON, when
the operating mode is changed (from IDLE Mode to RUN Mode), or when a
signal from a safety input device turns ON.
• The Monitored Input and all enabled optional inputs must be ON.
• And the Reset signal must be input correctly.
The Monitored Input and all enabled optional inputs must be ON.
If the following condition is met, the Reset Required Indication will become a
1-Hz pulse output.
• The Monitored Input and all enabled optional inputs must be ON.
• And Output Enable must be OFF.
If the Reset Signal is set to Low-High-Low, the Reset Required Indication will
turn ON when the next condition is met.
• The Reset signal turns ON.
The Reset Signal can be set in NE1A-series Controllers with unit version 1.0
or later.
• Low-High-Low
• Rising Edge
The number of inputs can be increased on the In/Out Setting Tab Page in the
function block property dialog box.
2 to 8 (Optional Input Settings)
Output Enable
Setting range
Setting range
Section 6-5
Default setting
Low-High-Low
Default setting
2
129