Omron K3NP - 1998 Operation Manual page 57

Period meter
Table of Contents

Advertisement

Setting Mode
48
8. Press the Shift Key to display the set value 10 00 for changing.
Set Value LED Display Model
9. Press the Up and Shift Keys to set the value to 10 -1 . The input will be vali-
dated automatically if no change is made for five seconds. The ps.ay pres-
caling value Y (exponent) of input A setting will be displayed again.
Note Press the Mode Key to enter the set value immediately. The decp
decimal point position setting will be displayed for setting the next pa-
rameter.
Set Value LED Display Model
10. Press the Mode Key to display the decp decimal point position setting.
Set Value LED Display Model
11. Press the Shift Key to display %%%%% for changing.
Set Value LED Display Model
12. Press the Shift Key to set %%%%.% . The input will be validated automatically if
no change is made for five seconds. The decp decimal point position setting
will be displayed again.
Note Press the Mode Key to enter the set value immediately. The p.bank
prescaling bank setting will be displayed for setting the next parame-
ter.
Set Value LED Display Model
When no operation is executed for five seconds
Set Value LED Display Model
Section 4-2
Basic Model
Basic Model
Basic Model
Basic Model
Basic Model
Basic Model