Protect Mode

4-3-3 Protect Menu ( prot )

All Key Protect
all
FUNCTION
SETTING
SETTING
Follow the steps described below to set the key protect to ON.
EXAMPLE
1, 2, 3...
· The operation of all keys can be prohibited in the protect menu.
Setting
kpon: Key protect ON
kpoff: Key protect OFF
Set Value LED Display Model
1. Press the Mode Key for more than one second while the prot protect menu
is displayed. The all all key protect setting will appear.
Set Value LED Display Model
2. Press the Shift Key to display the prior setting kpoff for changing. The
PROG indicator will flash.
Set Value LED Display Model
3. Press the Up Key to display kpon . The setting will be validated automatically
if no change is made for five seconds. The all all key protect setting will be
displayed again.
Note Press the Mode Key to enter the setting immediately. The next pa-
rameter will be displayed for setting.
Set Value LED Display Model
Default
kpoff
Basic Model
Basic Model
Basic Model
Basic Model
When no operation
is executed for five
seconds