Section 7 Bcd Output - Omron K3NP - 1998 Operation Manual

Period meter
Table of Contents

Advertisement

Connectors
Applicable Connectors
Terminal
Signal name
number
36
LL
37
COM
Note
1. Terminals 1, 25, and 37 have the same COM.
2. Refer to 2-3 Output Board for comparative outputs.
Use the connector provided with the K3NP or an equivalent connector for the
cable connecting to the BCD output connector.
The following connectors are provided with the K3NP.
Plug:
XM2A-3701 (OMRON)
Hood: XM2S-3711 (OMRON)
The depth required for the installation of the K3NP is 200 mm min. in consider-
ation of the space required by the cable.
Connecting Conditions
Refer to the following for the connecting conditions of each I/O. Refer to 2-3 Out-
put Block for output signals HH through LL.
· Input
Input current with no voltage input:
Signal level
ON voltage:
OFF voltage:
· Output
Rated load voltage:
Rated load current:
Current leakage:
Signal
direction
Output
LL output (See note 2.)
Output
GND:VO (See note 1.)
10 mA
1.5 V max.
3 V min.
24 VDC
10 mA
10 mA max.
Section 7-1
Use
95