Teaching Function

6-1

Teaching Function

6-1-1 Set Value

1, 2, 3...
SETTING
Follow the steps described below to set the HH set value of bank 1 by using the teaching
EXAMPLE
function.
1, 2, 3...
88
· The K3NP is provided with a teaching function that can set an actual measured
value as a set value without any front panel key input.
This function is useful for setting parameters while checking the operating sta-
tus of the K3NP.
· The teaching function can be used to set the setting, scaling values, and linear
output range. The TEACH indicator will be lit if a parameter that can use the
teaching function is displayed.
· A setting value can be set with the actual input instead of key input in the setting
mode.
· Follow the steps below to teach the setting value.
1. Press the RESET/TEACH Key for more than one second while the parame-
ter is displayed. The process value will be displayed and the teaching indica-
tor will flash.
2. Press the RESET/TEACH Key again to retrieve the process value immedi-
ately before the key was pressed as a set value. The teaching indicator will
be lit and the parameter will be displayed. Press the Escape Key to interrupt
teaching.
Set Value LED Display Model
1. Press the RESET/TEACH Key for more than one second while the parame-
ter is displayed. The process value will be displayed and the teaching indica-
tor will flash.
Set Value LED Display Model
2. Press the RESET/TEACH Key again to retrieve the process value immedi-
ately before the key was pressed as a set value for changing. The teaching
indicator will be lit and the parameter is displayed.
Set Value LED Display Model
Section 6-1
Basic Model
Basic Model
Basic Model

Advertisement