Setting Mode
SETTING
Follow the steps described below to input the following.
EXAMPLE
1, 2, 3...
Setting value bank = 2
HH setting value = "8000"
H setting value = "6000"
L setting value = "4000"
LL setting value = "2000"
Set Value LED Display Model
1. Press the Mode Key for more than one second while the sUset setting value
menu is displayed. The s.bank setting value bank setting will be displayed.
Set Value LED Display Model
2. Press the Shift Key to display the set value 1 for changing. The PROG indi-
cator will flash.
Set Value LED Display Model
3. Press the Up Key to set the value to 2 . The input will be validated automati-
cally if no change is made for five seconds. The s.bank setting value bank
setting will be displayed again.
Note Press the Mode Key to enter the set value immediately. The sU2.hh
HH setting value setting of bank 2 will be displayed for setting the next
parameter.
Set Value LED Display Model
4. Press the Mode Key to display the sU2.hh HH setting value of bank 2 setting.
Set Value LED Display Model
5. Press the Shift Key to display the set value 99999 for changing. The PROG
indicator will flash.
Set Value LED Display Model
Section 4-2
Basic Model
Basic Model
Basic Model
Basic Model
Basic Model
Basic Model