Elapsed Time: f4

3-4
Elapsed Time: f4
FUNCTION
Application example
INA
T
1
HOLD
Display Value previously
measured
SETTING
REFERENCE
28
Basic Operation
Displays in seconds the time period (T) that INA is ON. If another unit of mea-
surement is required, input an appropriate prescale value. Obtain display value
D as follows:
D (s) = T x a
T: Time period (sec) INA is ON
a: prescale value
To set a prescale value, refer to 4-2-4 Prescaling Menu.
T
T
R
2
a
T
X
1
Refer to the following table to set the most suitable prescaling value.
Mode
Elapsed time
Where,
with operating mode 4, INB input is disregarded.
Note The K3NP can display time, minute, and second. Refer to page 54 for details.
Refer to 4-2 Setting Mode.
Measures the pressing time of a printing machine.
T
3
a
T
X
2
Unit of display
Prescale value
value
sec
1
min
1/60
Section 3-4
T
4
a
T
X
4
T
: Recovery time
R