Time Difference: f3

3-3

Time Difference: f3

FUNCTION
Value previously
Display
measured
SETTING
REFERENCE
Application example
Basic Operation
Displays the time (T) in seconds between INA turning ON and INB turning ON. If
another unit of measurement is required, input an appropriate prescale value.
Obtain the display value D as follows:
D (m/min) = T x a
T: The time (sec) between INA turning ON and INB turning ON
a: Prescale value
To set a prescale value, refer to 4-2-4 Prescaling Menu.
T
R
Refer to the following table to set the most suitable prescaling value.
Mode
Time difference
Note The K3NP can display time, minute, and second. Refer to page 54 for details.
Refer to 4-2 Setting Mode.
Measures the time taken by an
object to pass between A and B.
Unit of display
Prescale value
value
sec
1
min
1/60
Section 3-3
T
: Recovery time
R
25