Interval: F6; Interval: F6 - Omron K3NP - 1998 Operation Manual

Period meter
Table of Contents

Advertisement

Interval: f6

3-6

Interval: f6

FUNCTION
Application example
INA
INB
C
1
HOLD
Display Value previously
measured
SETTING
REFERENCE
34
Basic Operation
Counts the number of pulses of INA between successive instances of INB turn-
ing ON and displays the result. Obtain display value D as follows:
D (pulse count) = C x a
C: Pulse count of INA while INB input is ON
a: Prescale value
To set a prescale value, refer to 4-2-4 Prescaling Menu.
C
T
2
R
a
C
X
1
Refer to the following table to set the most suitable prescaling value.
Mode
Interval
Na: Number of pulses per revolution at A input
pDa: Circumference (m) per revolution from A input
Note The K3NP can display time, minute, and second. Refer to page 54 for details.
Refer to 4-2 Setting Mode.
Measures the distance between the slits.
C
3
a
C
X
2
Unit of display
Prescale value
value
mm
1000
cm
100
m
p
Da/Na
Section 3-6
C
4
a
C
X
4
T
: Recovery time
R
p
Da/Na
p
Da/Na