Omron CX-INTEGRATOR - V1.1 Operation Manual page 81

Table of Contents

Advertisement

2-2
Connecting Online to the Relay PLC
2-2-2
Procedures
Item
Device Name
Device Type
Network Type
Click the Settings Button to display the Network Settings Dialog Box for each type of
network. Details are described here for Toolbus, SYSMAC WAY, and Ethernet. Refer
to the CX-Programmer Operation Manual for other methods.
2-14
Relay Device (fixed)
Series
Device Type
CS Series
CS1H
CS1G/CJ1G
CS1G-H
CS1H-H
CS1D-H
CS1D-S
CJ Series
CS1G/CJ1G
CJ1M
CJ1G-H
CJ1H-H
CP-Series
CP1H-XA
CP1H-X
NSJ Series
NSJ
-
CompoWay/F
Device
Select one of the following network types.
Network type
Contents
Toolbus
Select to connect the computer with a direct serial
connection using the Toolbus protocol.
Note:
SYSMAC WAY
Select to connect the computer with a direct serial
connection using the SYSMAC WAY protocol.
Note:
Ethernet
Select to connect the computer directly to an Ethernet
network using the Ethernet UDP/IP protocol.
Ethernet (FINS/TCP)
Select to connect the computer directly to an Ethernet
network using the Ethernet TCP/IP protocol.
FinsGateway
Select to use FinsGateway for communications.
(Selected when using FinsGateway for all
communications.)
Controller Link
Select to connect the computer directly to a Controller
Link network through a Controller Link Support Board.
SYSMAC LINK
Select to connect the computer directly to a SYSMAC
LINK network through a SYSMAC LINK Support
Board.
CompoWay/F
Select to connect the computer with a direct serial
connection to a CompoWay/F slave.
USB
Select to connect the computer directly to an
NSJ-series NSJ Controller using a USB cable.
Contents
CPU Unit model
CS1H-CPU67/66/65/64/63(-V1)
CS1G-CPU45/44/43/42(-V1)
CS1G-CPU45H/44H/43H/42H
CS1H-CPU67H/66H/65H/64H/63H
CS1D-CPU67H/65H
CS1D-CPU67S/65S/44S/42S
CJ1G-CPU45/44
CJ1M-CPU23/22/21/13/12/11
CJ1G- CPU45H/44H/43H/42H
CJ1H-CPU67H/66H/65H
CP1H-XA@@@@-@
CP1H-X@@@@-@
G5D (Used for the NSJ5-TQ0@-G5D,
NSJ5-SQ0@-G5D, NSJ8-TV0@-G5D,
NSJ10-TV0@-G5D, and
NSJ12-TS0@-G5D.)
Select CompoWay/F Device to connect
the computer running CX-Integrator
directly as a CompoWay/F slave using
serial communications.
The Toolbus (peripheral) protocol is faster
than the SYSMAC WAY protocol. Serial
connections are generally made using this
network type.
The SYSMAC WAY protocol enables 1:N
connections, which are not possible for the
Toolbus protocol.