Intended Audience; Safety Precautions - Omron CX-INTEGRATOR - V1.1 Operation Manual

Table of Contents

Advertisement

1

Intended Audience

1
Intended Audience
2

Safety Precautions

!Caution When performing any of the following operations, always check the network
!Caution When changing the target PLC to any PLC other than the relay PLC, check
!Caution When transferring parameters that have been created or edited on the
!Caution When changing or removing a routing table (see note), be sure to update the
xvi
This manual is intended for the following personnel, who must also have
knowledge of electrical systems (an electrical engineer or the equivalent).
• Personnel in charge of installing FA systems
• Personnel in charge of designing FA systems
• Personnel in charge of managing FA systems and facilities
address and node address of the other node (PLC) and the node address
and unit number of the mounted Unit (PLC CPU Bus Unit or Special I/O Unit)
or the node address of the Component (DeviceNet Master/Slave or
CompoWay/F Slave), and be sure that these operations can be performed
safely for the current status of the node (Unit or Component):
• Transferring parameter or program data to the other node
• Changing the operating mode of the other node
Unexpected operation may result if parameter or program data is transferred
to the wrong node (DeviceNet Master/Slave or CompoWay/F Slave), the
operating mode of the wrong node is changed, or the other node is not in a
suitable status to receive the program or parameter data or the operating
mode change.
the node address and node number of the target PLC carefully before
executing the change. Unexpected operation and injury may result if the
wrong PLC is set as the target PLC.
• Changing the operating mode
• Transferring or verifying user-set data link tables
• Transferring or verifying routing tables
• Performing I/O table operations (including transferring CPU Bus Unit or
Special I/O Unit parameters)
Note
Operations performed from the CX-Integrator are performed for the target
PLC, which is not necessarily the same as the relay PLC.
computer to actual Units (PLC CPU Bus Units or PLC Special I/O Units) or to
actual Components (DeviceNet Masters/Slaves or CompoWay/F Slaves),
always check the identifying number of the actual Units or Components (i.e.,
the unit numbers and unit addresses or node addresses) before executing
the transfer. Unexpected operation and injury may result if parameters are
transferred to the wrong Unit or Component.
display for the Online Connection Information Window. The display for the
Online Connection Information Window could possibly be different from the
actual network status. If operations are executed without first updating the
display, particularly online operations in the Network Configuration Window, it
could cause data to be mistakenly read or written for the wrong network or
node address or unit number.