Omron CX-INTEGRATOR - V1.1 Operation Manual page 30

Table of Contents

Advertisement

1-2
Specifications
1-2-1
CX-Integrator Specifications
Item
PLCs that are
Series
accessible as target
CS Series
PLCs
Note: The target PLC
is the PLC actually
being accessed, e.g.,
to upload/download
the PLC's network
configurations.
CJ Series
CP-Series
NSJ
Series
Note:
Supported
The following communications are possible for a directly connected target PLC.
communications
Supported network
communications
Supported serial
communications
Note: Accessing PLC Communications Across Network Layers
If relay network routing tables are set, a PLC on a different network layer than the network of the
PLC connected to the CX-Integrator can be set as the target PLC.
1-10
Device type
CS1H
CS1H-CPU67/66/65/64/63(-V1)
CS1G/CJ1G CS1G-CPU45/44/43/42(-V1)
CS1G-H
CS1G-CPU45H/44H/43H/42H
CS1H-H
CS1H-CPU67H/66H/65H/64H/63H
CS1D-H
CS1D-CPU67H/65H
Note: When using a pre-Ver. 1.1
CS1D-S
CS1D-CPU67S/65S/44S/42S
CS1G/CJ1G CJ1G-CPU45/44
CJ1M
CJ1M-CPU23/22/21/13/12/11
CJ1G-H
CJ1G- CPU45H/44H/43H/42H
CJ1H-H
CJ1H-CPU67H/66H/65H
CP1H-XA
CP1H-XA@@@@-@
CP1H-X
CP1H-X@@@@-@
NSJ
G5D (Used for the NSJ5-TQ0@-G5D,
NSJ5-SQ0@-G5D, NSJ8-TV0@-G5D,
NSJ10-TV0@-G5D, and
NSJ12-TS0@-G5D.)
The CS/CJ-series PLC must have a lot number of 030201 or later (manufactured 1
February 2003 or later) to start the CX-Designer and transfer screen data to an NS-series PT
from the CX-Designer through the PLC. The following PLCs can be used:
CS1G-H, CS1H-H, CS1D-S, CJ1M, or CJ1H-H. (The CS1D-H cannot be used.)
Ethernet (Access is possible only to CS/CJ-series PLCs, NS-series PTs,
and computers with FinsGateway on the Ethernet network. For
CVM1/CV-series PLCs, only display functions are supported.)
Controller Link (Access is possible only to CS/CJ/CP-series PLCs,
NS-series PTs, and computers with FinsGateway on the Controller Link
network.) For C200H-series PLCs and CVM1/CV-series PLCs, only
display functions are supported.)
Note:
being used, it is possible to monitor and troubleshoot PLC models in
the Controller Link network other than CS/CJ-series PLCs.
SYSMAC LINK (Monitoring is possible only to CS/CJ-series PLCs,
NS-series PTs, and computers with FinsGateway on the SYSMAC LINK
network.)
DeviceNet (CS/CJ-series DeviceNet Units, C200H DeviceNet Master
Units, or CVM1/CV-series DeviceNet Master Units)
Note:
Unit can be used through a CS/CJ-series DeviceNet Unit.
CompoWay/F (CS/CJ-series CPU Units must be unit version 3.0 or later.)
Serial Communications Boards and Serial Communications Units must be
unit version 1.2 or later. Only slaves for which CPS files are installed on
the computer can be accessed.
NT Links (Connection is possible only for NS-series PTs with model
numbers ending in V1 or later.)
Specification
CPU Unit model
CS1D-H CPU Unit, use it as if it
were a CS1H-H CPU Unit.
When the Controller Link Network Diagnosis application is
A C200H-DRM21-V1 or CVM1-DRM21-V1 DeviceNet Master
Note: CompoWay/F cannot be
used with a built-in serial
port on the CPU Unit.
Note: A CPU Unit with unit
version 3.0 or later must be
used when using
CompoWay/F with a
built-in serial port on the
CPU Unit
Note: CompoWay/F cannot be
used with a built-in serial
port on the CPU Unit.
Note: A CPU Unit with unit
version 3.0 or later must
be used when using
CompoWay/F with a
built-in serial port on the
CPU Unit
Note: CompoWay/F cannot be
used with a built-in USB
port on the CPU Unit. It
can be used with a serial
communications port.
Note: CompoWay/F can be used
on serial port C (RS-232C
port) on the Controller
Section of the NSJ
Controller.