6-7 Master Parameter Editing Details (Tab Descriptions)
6-7-3 Editing Device Parameters on 3G8F7-DRM21 DeviceNet PCI Board Scanner
6-7-3
Editing Device Parameters on 3G8F7-DRM21 DeviceNet PCI
Board Scanner
The following dialog box will be displayed when the 3G8F7-DRM21 DeviceNet PCI
Board Scanner is selected.
The Edit Device Parameters Dialog Box consists of the following four tab pages.
General
Communication Cycle Time
Slave Function
Message Timer
6-26
Tab
Registers the device with the scan list and makes I/O allocations
automatically.
Sets the communication cycle time.
Makes necessary settings that enable the slave function.
Makes monitor timer settings for message communications (both
explicit and FINS message
communications).
Description