RPM Limiter Specifications

Model
Max RPM
50cc
7400
90cc
8400
NOTE: There are no timing advance marks stamped
on the flywheel to read with a timing light.

Ignition Coil Test

Measure between
the two wire tabs for
Primary reading.
Test Description
Ignition Coil Primary Winding
Ignition Coil Secondary Winding
(With Cap Installed)
(Without Cap Installed)
Spark Plug Resistor Cap
CDI Output Test
Using Peak Reading Adaptor
Re-connect all wires to the CDI box. Disconnect the white/blue
(WH/DB) CDI output wire from ignition coil primary terminal.
Install the Peak Reading Adaptor (PV-39991) to your meter and
connect one meter lead to engine ground and the other to the
(WH/DB) CDI Output wire at the ignition coil. Set meter to read
DC Volts. Crank engine and verify CDI output to the ignition
coil. When finished, reconnect CDI output wire to ignition coil.
Connect Meter
Output Test
Leads To:
WH/DB to
CDI Output
Engine Ground
Ignition
Timing
33.5° BTDC
33.5° BTDC
Resistance
0.2 Ω ± 20%
8 K Ω ± 20%
3 K Ω ± 20%
5 K Ω
Reading
180 DC Volts ± 20%

Pulser Coil Output / Resistance Tests

Disconnect the 4-wire connector at the CDI box. Install the Peak
Reading Adaptor (PV-39991) to your meter and connect one
meter lead to the dark blue / black wire (DB/BK) and the other
to engine ground. Set meter to read DC Volts. Crank engine and
verify pulser coil output.
Connect
Voltage
Meter Leads
Test
Between:
DB/BK to
Pulser Coil
Engine Ground
If readings are within specifications, test the resistance value of
the pulser coil. When finished, reconnect the 4-wire connector
to CDI box.
Connect
Ohm Test
Meter Leads To:
Pulser Coil
Blue to Black
Pulser Coil Testing
ELECTRICAL
Reading
(With Peak Reading Adapter)
5 DC Volts minimum @
cranking RPM
Ω Reading
150 Ω ± 20%