Rpm Limiter Specifications; Ignition Coil Test; Cdi Output Test Using Peak Reading Adaptor; Pulser Coil Output / Resistance Tests - Polaris RZR 170 2009 Service Manual

Table of Contents

Advertisement

RPM Limiter Specifications

Model
Max RPM
170cc
8000
NOTE: There are no timing advance marks stamped
on the flywheel to read with a timing light.

Ignition Coil Test

Measure between
the two wire tabs for
primary reading.
Test Description
Ignition Coil Primary Winding
Ignition Coil Secondary Winding
(With Cap Installed)
(Without Cap Installed)
Spark Plug Resistor Cap
CDI Output Test
Using Peak Reading Adaptor
Re-connect all wires to the CDI box. Disconnect the (BLACK/
YEL) CDI output wire from ignition coil primary terminal.
Install the Peak Reading Adaptor (PV-39991) to your meter and
connect one meter lead to engine ground and the other to the
(BLACK/YEL) CDI output wire at the ignition coil. Set meter
to read DC Volts. Crank engine and verify CDI output to the
ignition coil. When finished, reconnect CDI output wire to
ignition coil.
Connect Meter
Output Test
Leads To:
BLK/YEL to
CDI Output
Engine Ground

Pulser Coil Output / Resistance Tests

Disconnect the 4-wire connector at the CDI box. Install the Peak
Ignition
Reading Adaptor (PV-39991) to your meter and connect one
Timing
meter lead to the dark blue / black wire (DB/YEL) and the other
N/A
to engine ground. Set meter to read DC Volts. Crank engine and
verify pulser coil output.
Pulser Coil
If readings are within specifications, test the resistance value of
the pulser coil. When finished, reconnect the 4-wire connector
to CDI box.
Resistance
0.2  ± 20%
8 K  ± 20%
3 K  ± 20%
5 K 
Reading
180 DC Volts ± 20%
Connect
Voltage
Meter Leads
Test
(With Peak Reading Adapter)
Between:
DB/YEL to
Engine Ground
Connect
Ohm Test
Meter Leads To:
Pulser Coil
DB/YEL to Black
ELECTRICAL
Reading
5 DC Volts minimum @
cranking RPM
Reading
151  ± 20%
8.11
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

R09va17aa

Table of Contents