Technical specifications

9.1

Applicability of technical specifications

Note
The following technical specifications only apply under the following conditions:
• The device is in good working order.
• The fan cover and filter mat are installed.
• The device is closed.
• The connected I/O devices meet the requirements for the respective area of application
(interference emission according to EN 61000-6-3 / IEC 61000-6-3, immunity to
interference according to EN 61000-6-2 / IEC 61000-6-2).
9.2

General technical specifications

See the note in "Applicability of technical specifications (Page 128)".
Article number
Dimensions
Weight
Supply voltage (U
; AC)
N
Transient overvoltages
Input current
128
Device with standard enclosure
6AG4103-6...-.... (for details, refer to the ordering documentation)
481.4 x 176.6 x 446.6 (W× H × D in mm)
Detailed dimensional specifications can be found in "Dimension drawings of the device
(Page 140)".
15 up to 23 kg; depending on the equipment
Power supply unit 550 W; AC:
100 V to 240 V AC (-15%; +10%)
Device is designed for connection to supply with overvoltage category II
(Transient overvoltages up to 2500 V)
550 W power supply unit:
Continuous current at 100 V: ≤ 8 A
Continuous current at 230 V: ≤ 4 A
At startup ≤ 80 A for 3.6 ms
Information on the dimensioning of fuses in higher-level system circuits
A fuse that is designed for the following tripping current is integrated in the power supply unit of
the IPC.
Typical 6.3 A (for power supply unit 550 W)
The pulse currents during startup are also taken into account by the "time lag" type. In the case
of a fault, this fuse ensures the correct disconnection of the device from the power supply sys-
tem.
If you connect additional devices to the higher-level power supply circuit, use the following
fuses:
> 6.3 A (with 550 W power supply unit).
The tripping characteristic of the higher-level protection must take into account the starting
currents of both the IPC and the other devices.
Device with short enclosure
481.4 x 176.6 x 356.6 (W × H × D
in mm)
Client SIMATIC IPC RC-545A
Operating Instructions, 03/2024, A5E53092314-AA