COMSPHERE 3600 Series Data Service Units

Status Indicators

Status indicators continuously provide information on
the current operating condition of the DSU or DBM.
Table 3-1 describes all status indicators.
Model 3610 DSU status indicators appear on the
front panel.
The carrier-mounted Model 3611 status indicators
appear on the SDCP.
LED Label Color
OK
Green
Health and status indicator: DSU operation is normal. The OK LED flashes two times per second
when a message from an NMS is present. When lit, the DSU has not detected any alarm listed
under Alrm, below.
Alrm
Red
Health and status indicator: There is an alarm in the local or remote DSU, DBM, or DDS facility, or
there is a corrupted configuration. For a DSU with TDM or MCMP, the alarm may be in the
communications path between the DSU and TDM or MCMP circuit card.
Alarms at the local or remote DSU cause the Alrm status indicator to light on the affected DSU.
Refer to Table E-5, Device Health and Status Messages, for further details. DBM health and
status messages are in Document No. 3610-A2-GB49.
Test
Yellow When the active core is being tested, the active DSU or DBM device is either performing a test or
other DSUs or DBMs are in Test mode. The DSU or DBM is automatically put into Test mode
when a remote DSU or DBM is performing a test disruptively. A DSU or DBM in Test mode has
the DTE interface turned Off.
DSU with TDM or MCMP: Any test involving the TDM or MCMP also involves the DSU. The test
is integrated into the DSU's Health and Status report. When the active core is being tested, any
port included in the active core is also tested.
Dial
Yellow DBM is active:
TXD, RXD,
Green
DTE status indicators: Internal lead states at the DSU/DTE interface for circuit designations:
RTS, CTS,
DSR, DTR,
LSD
DSU with TDM or MCMP: The circuit external lead states for any TDM or MCMP ports can be
selected through the front panel's Control branch.
Model 3610 DSU: The monitored port is displayed on the front panel LCD.
Model 3611 DSU with TDM or MCMP:
Front Panel
Yellow The currently selected DSU at the SDCP: The SDCP addresses one DSU at a time.
(Model 3611
Model 3611 DSU with TDM or MCMP: The TDM or MCMP circuit card has the same address as
only)
the associated DSU and is also addressed.
3-4
DSU Status Indicators
Rapid flashing: Call establish in progress
Slow flashing:
Call established but in Standby mode
Steady ON:
Backup call established and active
Control circuit active (CTS, DSR, DTR, LSD, and RTS) or
Data circuit spacing (RXD and TXD)
The TDM or MCMP faceplate indicates the monitored port with port LED lit.
DTR is always on. Refer to DTE Status on front panel for DTR status.
December 1996
OK Alrm
Network/Device
Alarm
Mode
Table 3-1
Description
LEDs
Test Dial TXD RXD
RTS CTS
DSR
103
104
105
106
107
Test
Dial
DTE Status
Backup
Indicators
3610-A2-GB46-60
DTR LSD
108
109
496-14716-01