Paradyne COMSPHERE 3610 User Manual page 86

Data service units
Hide thumbs Also See for COMSPHERE 3610:
Table of Contents

Advertisement

Message
Devic
Device Failure. One of the following major alarms is
in effect:
Configuration Corrupt
DSU Device Failure
MUX Device Failure
DialBU
Dial BackUp Mode.
DialCN
Dial Connect.
DialTn
Dial Tone Test failure.
Disab
Indicates DSU, DBM, or Port nn is disabled
( nn = 1–6).
DTR
DTE alarm.
ExtLd
External lead alarm A or B.
Facil
DDS facility alarm. Indicates a network facility
alarm.
MAJOR
Indicates a major alarm from a DATAPHONE II
device.
MUX
MUX (TDM or MCMP) failure.
NoResp
No response. The active poll list member did not
respond.
Normal
Active poll list member reports no alarm or status.
RPower
Redundant power supply alarm.
Stndby
Dial standby.
Stream
Streaming terminal.
SubSpd
Subnormal operating speed.
Test
Test mode. DSU test, DBM test, or Port nn test
( nn = 1–6).
Thresh
Threshold exceeded.
TribTm
Tributary time-out.
Trunc
Subtree truncation.
3610-A2-GB46-60
Table E-6
Subnetwork Health and Status Messages
Condition
December 1996
Troubleshooting and Front Panel Messages
Action
See Table E-5 for conditions and action.
Indicates DBM is active.
Indicates DBM is in Standby mode.
Check the DBM facility.
Check status of address.
Data Terminal Ready lead is Off.
See External Alarm A message in Table E-5.
When facility working, remote status address is
available.
Verify DPII connection.
See MCMP or MUX CommunicFail message in
Table E-5.
Probable cause: facility problem, remote DSU
problem, or poll list incorrect.
Status message.
See Redun Pwr Alarm message in Table E-5.
Status message.
See Prt nnn Stream Term message in Table E-5.
See Sub-normal Speed message in Table E-5.
Status message.
See OutofFrame Thresh message in Table E-5.
Multipoint configuration with no response.
See Subtree Truncat message in Table E-5.
E-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3611Comsphere 3600 series

Table of Contents