COMSPHERE 3600 Series Data Service Units
Message
LPDA&PrtSPIncmpt
LPDA enabled is incompatible with port 1 speed
set to less than 4.8 kbps with:
A digital DBM and diagnostic type set to
NonDisruptive, or multipoint with symmetric
mode disabled and port speed is less than
DDS speed, or MCMP.
Disruptive diagnostic type set to Br56 and
diagnostic type set to NonDisruptive, or
multipoint with symmetric mode disabled and
port speed is less than DDS speed, or
MCMP.
10BPC & 2 Stops
Two stop bits not available when number of bits
per character is set to 10. Need one start bit;
the maximum size of asynchronous character is
12 bits (ASPEN chip).
V.54&2500 Incmpt
Disruptive diagnostic type set to 2500 is
incompatible with V.54 Loopback enabled.
E-4
Table E-4
(2 of 2)
Configuration Error Messages
Condition
December 1996
Action
Change configuration option PrtSp(Kbps) to
4.8 kbps or higher, or change Diag Type, or
enable M-PtSymPrt, or change MUX Funct to
not equal MCMP.
Change configuration option Disr Type to
Br56, or set PrtSp(Kbps) to the DDS speed, or
enable M-PtSymPrt. MCMP is not available
with symmetric mode and multipoint.
When the configuration option AsyncBit/Char is
set to 10, set the configuration option Stop Bits
to 1.
Set configuration option Disr Type for any value
but 2500, or disable configuration option V.54
Lpbk.