Advertisement

5. After changing and not saving configuration
options, the following prompt appears when the
or
key is pressed.
Save Options?
Yes
F1
6. If you press F1 for Yes, the Save To screen
appears.
Save to:
Activ
F1
Usr2
Usr3
MPTC MPTT
If Save to is not displayed, press
prompt appears.
When you press a function key from the Save to
screen, the DSU performs a verification routine to
ensure that the configuration options chosen are
compatible.
7. You must select SAVE for changes to take effect.
After selecting SAVE, the following screen
appears.
Edit/Save:
SAVE
F1
DBM
Gen
LPDA
Continue with network connections and verification
testing. When finalized, you can edit and save additional
configuration options.
3610-A2-GB46-60
No
F3
F2
Remt
Usr1
F3
F2
FacC
FacT
FacB
until the
DSU
Diag
F3
F2
Bckup
MUX
PrtSp
December 1996
Table 2-1
Default Configuration Option Sets
Load
from
Configuration Options
Activ
Active: Currently active configuration options for
the addressed DSU; use to change and save
configuration options.
Remt
Remote: Configuration options that can be
retrieved from a selected tributary DSU; these
will be from the tributary's Active set and
appear based on local hardware. They are
filtered when the front panel is locked.
The selected option set can then be displayed,
edited, and saved back to the same tributary,
another tributary, or the control DSU. The five
factory default option sets do not appear when
in Remote mode.
Remote is filtered for a multipoint tributary or a
unit with Diag Type of None.
Usr1
User 1: User-defined option sets.
Usr2
User 2: User-defined option sets.
*
User 3: User-defined option sets, and factory
Usr3
default settings for a DBM- X (Model 3611
DBM-D, DBM-I, DBM-S, and DBM-V; does not
function as a DSU).
FacC
Factory Control: Control DSU factory default
settings.
FacT
Factory Tributary: Tributary DSU factory default
settings.
FacB
Factory Digital Bridge: Central-site digital bridge
factory default settings. FacB is filtered when
MUX CCA is not installed.
MPTC Multipoint Control: Multipoint Control DSU
factory default settings. MPTC is filtered when
TDM CCA is installed.
MPTT Multipoint Tributary: Multipoint Tributary DSU
factory default settings.
*
When configuring a DBM- X , do not SAVE to Usr3.
Refer to Chapter 3, Chapter 4, and Appendix E for
details regarding configuration of your unit. Use the
Appendix B worksheet for recording configuration option
changes stored in Usr1, Usr2, or Usr3. For a complete list
of DSU factory default settings, refer to Table A-1.
Model 3610 Installation
Source Of
2-7