Displaying External Leads
Display (Displ) allows you to view the external lead
states. When you select Display, the External Leads status
report appears showing the current status of the general-
purpose external leads on the EIA-232-D/V.24 interface.
Input leads A (Pin 23) and B (Pin 19):
Off (
) when voltage on lead is less than +0.8V.
ON (
) when voltage on lead is more than +2.2V.
Output leads A (Pin 12) and B (Pin 13):
Off (
), –12V is applied to lead.
ON (
), +12V is applied to lead.
Change (Chang) allows you to change the state of the
two output leads. Examples include changing a lead to
signal a console operator or resetting a remote computer.

Reset

Selecting Reset will reset all connections and start a
power-up routine. When the PowerOnTst General
configuration option is disabled, the unit bypasses device
tests but continues to generate configuration error
messages if a major device error is detected.
While the DSU is executing power-up diagnostics, the
async terminal connection is ended and the async terminal
displays Device Reset. Once completed, the user needs to
login into the async terminal again.
NOTE
Reset is disruptive and can
affect your application data or
may cause your application
session to be dropped.
3610-A2-GB46-60

Remote Branch

The Remote (Remot) branch allows front panel access
to remote units.
Point-to-point configuration: access DSU at the
other end.
Multipoint configuration: enter DSU remote
addresses and access each unit.
When the Remote branch is accessed, the front panel
displays the local menu tree with the remote unit's data.
Local
When the remote unit status is displayed, an inverse
appears on the top left of the LCD, as shown below.
H/S:
F1
When changing configuration options:
At the Load from menu, select Activ to obtain the
remote unit's active configuration.
From the Edit/Save menu, press Save to and then
select Activ.
The remote end starts responding after SAVE is
pressed. After selecting SAVE, the responding message is
Command Complete or Command Fail. Use the
Remote branch to run tests or communicate with a
tributary. Refer to the Options section, page 3-14.
Remote does not appear as a menu selection for a
multipoint tributary or when the Diagnostic Type is set to
None (Table 4-2).
December 1996
Front Panel Operation
TOP-LEVEL MENU
Remot
Msgs
Address
495-12970a
0:31:08
9.6 DDS
F3
F2
3-17