Powering Up The Dsu; Power-Up Routine - Paradyne COMSPHERE 3610 User Manual

Data service units
Hide thumbs Also See for COMSPHERE 3610:
Table of Contents

Advertisement

COMSPHERE 3600 Series Data Service Units

Powering Up the DSU

CAUTION
The power cord and ac
transformer have a 3-wire
grounding-type plug with a
grounding pin. This is a safety
feature. Grounding of the unit
is vital to ensure safe
operation. Do not defeat the
purpose of the grounding
plug by modifying it or by
using an adapter.
Prior to installation, use an
outlet tester or voltmeter to
check the ac receptacle for
earth ground. If the power
source does not provide a
ground connection, consult
an electrician to determine
another method of grounding
the unit before proceeding
with the installation.
NOTE
Before connecting the DSU to
any network, ensure that
approved primary protectors
have been installed on the
circuit in accordance with Article
800 of the National Electric
Code, NFPA 70, in the United
States and Section 60 of the
Canadian Electric Code, Part 1,
in Canada.
2-4
Procedure
1. At the rear of the DSU, insert the round end of the
power cable into the receptacle labeled POWER.
3-Prong
Grounded
AC
Wall Outlet
2. Connect the 3-prong plug at the other end of the
cable to an ac outlet.

Power-Up Routine

When you apply power for the first time, the DSU
performs a power-up routine and:
Determines what hardware options are installed, if
any. These may include DBM and MUX for
TDM/MCMP.
Runs a Device Test on the DSU and each installed
hardware option. All front panel lights flash on and
off.
December 1996
5
V . 3
/ D C
C C
U P
C K
B A
E
L I N
E R
W
P O
Low
Voltage
AC Power
In
Table-Top
AC
Transformer
495-14703
3610-A2-GB46-60