Remote Command Response Frame - 0X97 - Digi XBee-PRO S2C Zigbee User Manual

Rf module
Hide thumbs Also See for XBee-PRO S2C Zigbee:
Table of Contents

Advertisement

API Operation

Remote Command Response frame - 0x97

Description
If a device receives this frame in response to a Remote Command Request (0x17) frame, the device
sends an AT Command Response (0x97) frame out the serial interface.
Some commands, such as the ND command, may send back multiple frames.
Format
The following table provides the contents of the frame. For details on frame structure, see
format.
Frame data fields
Frame type
Frame ID
64-bit source
(remote) address
16-bit source 
(remote) address
AT commands
Command status
Command data
Example
If a device sends a remote command to a remote device with 64-bit address 0x0013A200 40522BAA to
query the SL command, and if the frame ID = 0x55, the response would look like the following
example.
Frame data fields
Start delimiter
Length
Frame type
Frame ID
XBee/XBee-PRO® S2C Zigbee® RF Module
Offset Description
3
0x97
This is the same value that is passed in to the request.
4
5-12
The address of the remote device returning this response.
Set to the 16-bit network address of the remote device returning
13-14
this response. Set to 0xFFFE if unknown.
The name of the command.
15-16
0 = OK
17
1 = ERROR
2 = Invalid Command
3 = Invalid Parameter
4 = Remote Command Transmission Failed
18-n
The register data in binary format. If you set the register, the device
does not return this field.
Offset
Example
0
0x7E
MSB 1
0x00
LSB 2
0x13
3
0x97
4
0x55
Frame descriptions
API frame
191

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xbee s2c zigbee

Table of Contents