Frame descriptions

Remote Command Response frame - 0x97

Description
If a device receives this frame in response to a Remote Command Request (0x17) frame, the device
sends an AT Command Response (0x97) frame out the serial interface.
Some commands, such as the ND command, may send back multiple frames.
Format
The following table provides the contents of the frame. For details on frame structure, see
format.
Frame data
fields
Frame type
Frame ID
64-bit source
(remote)
address
Reserved
AT commands
Command
status
Command data
Example
If a device sends a remote command to a remote device with 64-bit address 0x0013A200 40522BAA to
query the SL command, and if the frame ID = 0x55, the response would look like the following
example.
XBee®-PRO 900HP/XSC RF Modules
Offset Description
3
0x97
This is the same value passed in to the request. If Frame ID = 0 in the
4
associated request frame the device does not deliver a response frame.
5-12
The address of the remote device returning this response.
Reserved.
13-14
The name of the command.
15-16
The least significant nibble indicates the command status:
17
0 = OK
1 = ERROR
2 = Invalid command
3 = Invalid parameter
4 = Remote command transmission failed
The most significant nibble is a bit field as follows:
0x40 = The RSSI field is invalid and should be ignored.
0x80 = Response is a remote command
18-n
The value of the requested register.