Modem Status Frame - 0X8A - Digi XBee-PRO S2C Zigbee User Manual

Rf module
Hide thumbs Also See for XBee-PRO S2C Zigbee:
Table of Contents

Advertisement

API Operation

Modem Status frame - 0x8A

Description
Devices send the status messages in this frame in response to specific conditions.
Format
The following table provides the contents of the frame. For details on frame structure, see
format.
Frame data fields
Frame type
Status
Example
When a device powers up, it returns the following API frame.
Frame data fields
Start delimiter
Length
LSB 2
Frame type
Status
Checksum
XBee/XBee-PRO® S2C Zigbee® RF Module
Offset
Description
3
0x8A
0x00 = Hardware reset
4
0x01 = Watchdog timer reset
0x02 =Joined network (routers and end devices)
0x03 = Disassociated
0x06 = Coordinator started
0x07 = Network security key was updated
0x0D = Voltage supply limit exceeded (PRO only)
0x11 = Modem configuration changed while join in progress
0x80+ = Ember Zigbee stack error
Offset
Example
0
0x7E
MSB 1
0x00
LSB 2
0x02
3
0x8A
4
0x06
5
0x6F
Frame descriptions