Do Command; Voltage Supply Monitoring) - Digi XBee-PRO S2C Zigbee User Manual

Rf module
Hide thumbs Also See for XBee-PRO S2C Zigbee:
Table of Contents

Advertisement

AT commands
Bit Description
0
Generate a preconfigured link key using the device's install code (KY will be ignored).
1
Network Leave Request Not Allowed. Indicates if a router node discards or accepts network
leave commands.
2
Reserved
3
Reserved
Verbose Joining Mode. See
4
Parameter range
0 - 0xFFFF
Default
0x00

DO command

Sets or displays the device options.
Bit field:
Bit Description
0
Reserved
1
Reserved for Smart Energy devices.
2
0/1 = First or Best Join. First join means the device joins the network through the first
acceptable Beacon response it receives. Best join means the device joins the network through
the strongest Beacon response it receives after searching all search mask channels.
3
Disable NULL transport key (coordinator only).
4
Disable Tx packet extended timeout.
5
Disable ACK for end device I/O sampling.
6
Enable high ram concentrator.
Enable NW to find new network before leaving the network.
7
Parameter range
0x00 - 0xFF
Default
0x00
%V (Voltage Supply Monitoring)
Reads the voltage on the Vcc pin in mV.
XBee/XBee-PRO® S2C Zigbee® RF Module
Extended Modem Status frame - 0x98
I/O settings commands
for a full description.
248