Frame descriptions

Remote Command Response frame - 0x97

Description
If a device receives this frame in response to a Remote Command Request (0x17) frame, the device
sends an AT Command Response (0x97) frame out the serial interface.
Some commands, such as the ND command, may send back multiple frames.
Format
The following table provides the contents of the frame. For details on frame structure, see
format.
Frame data fields
Frame type
Frame ID
64-bit source (remote) address 5-12
Reserved
AT commands
Command status
Command data
Example
If a device sends a remote command to a remote device with 64-bit address 0x0013A200 40522BAA to
query the SL command, and if the frame ID = 0x55, the response would look like the following
example.
Frame data fields
Start delimiter
Length
Frame type
Frame ID
Digi XBee3® DigiMesh 2.4 RF Module User Guide
Offset Description
3
0x97
This is the same value that is passed into the request.
4
The address of the remote device returning this response.
Reserved.
13-14
The name of the command.
15-16
0 = OK
17
1 = ERROR
2 = Invalid Command
3 = Invalid Parameter
18-n
The value of the requested register.
Offset
0
MSB 1
LSB 2
3
4
Remote Command Response frame - 0x97
Example
0x7E
0x00
0x13
0x97
0x55
API frame