a-TroniX Inverter AX-series, 3 ph
• Check if the input and output wires are damaged or aged. This check should
be performed at least every 6 months.
• Get the inverter panels cleaned and their security checked at least every 6
months.
NOTE
Only qualified individuals may perform the following works.

9. Decommissioning

9.1 Dismantling the Inverter

• Disconnect the inverter from DC (for 3ph only) Input and AC output.
Wait for 5 minutes for the inverter to fully de-energize.
• Disconnect communication and optional connection wirings.
Remove the inverter from the bracket.
• Remove the bracket if necessary.

9.2 Packaging

If possible, please pack the inverter with the original packaging. If it is no
longer available, you can also use an equivalent box that meets the following
requirements.
• Suitable for loads more than 30 kg.
• Contains a handle.
• Can be fully closed.

9.3 Storage and Transportation

Store the inverter in dry place where ambient temperatures are always between
-40 °C ~ +70 °C . Take care of the inverter during the storage and transportation;
keep less than 4 cartons in one stack. When the inverter or other related
components need to be disposed of, please ensure it is carried out according
to local waste handling regulations. Please be sure to deliver any inverter
that needs to be disposed from sites that are appropriate for the disposal in
accordance with local regulations.
atx002en0723
Page 123