14.2.5 T Type (user wired cable gland connections)
14.2.5.1 Overview—T-type connections
Location
The terminal board is located behind the input/ouput panel on T type models
Connection
IP66, NEMA 4X
Specification
Control
Parameter
cable
specification
Terminal Wire Size
Relay
Screen
Cable section
profile
Cable outside
diameter to
ensure ingress
rating
Cable conductors
Maximum
temperature
rating
Maximum cables
per gland
Data
24 AWG to 12 AWG
SPCO
0.25 Blade
Round
9.5 mm to 12 mm
(0.374 in to 0.472 in)
0.05 to 1.31 mm
2
(30 to 16 AWG)
stranded or solid
85 °C (185 °F)
1
NOTE 1
M2.5 Screw
240 V 5 A AC
resistive
Optional cable EMC
screen connection
to pump Earth.
Not a protective
earth or earth
bond test point.
NOTE 2
Max 10 mA
Max 50 V
wrt 0 V