Watson-Marlow qdos H-FLO Reference Manual page 120

Table of Contents

Advertisement

15.2.4 Units used in the PROFIBUS parameters
The following units are used in the PROFIBUS parameters
Name
DeciRPM
uL (microlitre)
15.2.5 User parameter data
Ext_User_Prm_Data_
Const[0]=
Byte 0
Byte 1
Byte 2
Field bus minimum speed
Byte 3
Field bus minimum speed
Byte 4
Field bus maximum speed
Byte 5
Field bus maximum speed
Byte 6
Byte 7
Byte 8
15.2.5.1 Pump model
Hex
0x00
15.2.5.2 Head type
Hex
0x00
ReNu 150 pumphead Santoprene / PFPE 7 bar (102 psi)
0x03
ReNu 300 pumphead Santoprene / PFPE 5 bar (73 psi)
0x04
0x05
ReNu 600 pumphead Santoprene / PFPE 2.5 bar (36 psi)
Explanation
1/10
of an RPM
th
1/1000
th
of a mL
User Parameter Data
0x00
0x00
Byte
Byte
0
1
Pump model
Head type
Fail safe
Fail safe speed
Fail safe speed
Description
ReNu 300 pumphead SEBS / PFPE 4 bar (58 psi)
Example
1205 deciRPM = 120.5 rpm
1,000,000 uL/min = 1000 mL/min = 1 L/min
0x00
0x00
0x00
0x00
Byte
Byte
Byte
Byte
2
3
4
Description
QFH
0x00
0x00
0x00
Byte
Byte
Byte
5
6
7
8
High Byte
Low Byte
High Byte
Low Byte
High Byte
Low Byte
Product
Code
0M3.6200.PFP
0M3.7200.PFP
0M3.7800.PFP
0M3.8200.PFP
120

Advertisement

Table of Contents
loading