Technical Specifications - RMG USZ 08 series Operating Instructions Manual

Ultrasonic flowmeter
Table of Contents

Advertisement

...........................................................................................................................................................................................................

Technical specifications

Power supply:
Measuring element:
ERZ 2000 USC:
Power input:
Measuring element:
ERZ 2000 USC:
Protection class:
Interfaces:
RS 485 0 (for RMGView):
RS 485 1:
RS 485 2 (with USE 09C):
(optional for the USE 09)
Current output:
Pulse outputs:
Sensor frequency:
Flow velocity:
Temperature range:
Measuring ranges:
Nominal diameter
mm
100
150
200
250
300
400
500
600
*
)
3-path flowmeter only as special design
...........................................................................................................................................................................................................
Manual USZ 08 · EN05 · 2015-06
24 VDC
24 VDC or 230 VAC
USE 09: 5 W
24 W
IP 65
9600 / 19200 / 38400 / 57600 baud
9600 / 19200 / 38400 / 57600 baud
9600 / 19200 / 38400 / 57600 baud
U
= 16 V
max
U
= 30 V
max
120 kHz or 200 kHz
-40 to + 40 m/s
-20° to +55°C (optional: -40°C to +55°C)
for custody transfer metering
Measuring range (m³/h)
inches
Qmin
4
13
6
20
8
40
10
65
12
80
16
130
20
200
24
320
TECHNICAL SPECIFICATIONS
USE 09C: 15 W
Load resistance: max. 400 Ω
f
= 5 kHz
max
Qmax
1000
2500
4000
6500
10000
16000
25000
40000
Acoustic paths
3*
/ 6
)
3*
/ 6
)
6
6
6
6
6
6
59