RMG TME 400-VM Operating Manual page 74

Hide thumbs Also See for TME 400-VM:
Table of Contents

Advertisement

4 Operation
4.3.3.7
Coordi-
Name
nate
Z04
X:Y maximum pulse
error
70
Z05
X:Y maximum pulse
Z10
Error register 1
Z11
Error register 2
Z12
Status register 1
Z13
Status register 2
Z15
Code word release
Z16
Change code word
Z17
Device type
Z24
Display active max.
Z25
Volume metering mode
Manual TME400-VMF · EN11 · January 22nd, 2024
Settings
Description
A differential circuit compares the metered pulse of measuring and
comparison channels alternatingly. Every deviation is counted inter-
nally. An alarm is generated if the adjusted limit value is exceeded.
The failure counter is reset to 0 for each new measurement or after
the maximum number of pulses (Z05) is reached.
see above
Display value
Display value
Display value
Display value
Note
The code word for the TME 400 is:
This is always displayed as " **** " in the parameter archive.
With entry of this code word, the protected parameters can be
changed.
A new password can be defined here.
0
1
2
3
0
1
2
The time during which the display is active for tests is selected as
60 minutes. In general, however, it must be observed that higher en-
ergy consumption is associated with this time, so this time should be
selected as short as possible, if possible.
0
1
2
3
4
5
6
7
8
TME 400-VM (default)
TME 400-VC
TME 400-VMF (MID)
TME 400-VCF (MID)
1 minute (default)
5 minutes
60 minute test
1-channel without errors (default)
1-channel stop on error
1-channel run on error
1-channel start / stop
1-channel reset
2-channel stop on error
2-channel run on error
2-channel without X:Y error
1 Channel Start/Stop Mode 2
1 2 3 4