1 Introduction
The components of the gases must be within the concentration limits according to EN
437:2009 for test gases. Safe operation is guaranteed with these specified gases.
Other gases on request
20
1.3.6.1
The TME 400 can be used in hydrogen-containing natural gas up to pure hydrogen.
There are no safety-related concerns for this use.
Notice
In accordance with the German TR-G19 – the TME 400 is suitable and ap-
proved for use in custody transfer applications – in natural gases with a
maximum hydrogen content of 10 mol-%, with the accuracy specified in
chapter 1.4.2.9 Measuring accuracy.
Since there are currently no certified test rigs in Germany to calibrate meters with
higher hydrogen-containing gases, an accuracy above 10 mol-% cannot be tested or
certified.
Not custody transfer measurements are of course possible in natural gases with a hy-
drogen content above 10 mol%. However, a reduced measuring range must be taken
into account if applicable. Please contact RMG for further information.

1.4 Areas of application

The following chapter provides handling instructions for the TME 400 turbine meter
for the purpose of safe and reliable operation of the device.
Note
Some of the settings described below must not be made until you have read
the explanations in chapter 4 Operation.
Manual TME400-VMF · EN11 · January 22nd, 2024
Suitability and compatibility for natural gas containing H2