RMG TME 400-VM Operating Manual page 70

Hide thumbs Also See for TME 400-VM:
Table of Contents

Advertisement

4 Operation
F10
Calibration value 4mA
F11
Calibration value 20mA Calibration: Current value 20mA (after activation of current source)
F12
Module serial number
Coor-
Name
dinate
66
F01
Current
F02
Current mode
F03
Current source
F04
Figure below
F05
Picture above
F06
Current specification
F07
Current moderation
F10
Calibration value 4mA
F11
Calibration value 20mA
F12
Module serial number
4.3.3.4
Coordi-
Name
nate
G01
Current error
G02
Software version
G04
Serial number
G05
Firmware checksum
G06
Measuring point
G18
Meter number
G21
CRC metrological
Param. EEprom
G23
Date of Battery
Exchange
G24
Remaining Battery
Capacity
G25
Battery Change
G26
Operating Hours
G19
Meter size
G20
Date of last battery re-
placement
Manual TME400-VMF · EN11 · January 22nd, 2024
Calibration: Current value 4mA (after activation of current source)
Serial number of the current module
Modbus
register
330
657
658
659
661
663
665
667
669
671
Error / type plate
Description
Identifies the current error
Shows the version number of the firmware in the TME 400.
Serial number of the TME 400
Shows the checksum of the firmware (important for TME 400-VMF
and TME 400-VCF in custody-transfer applications)
Possibility of numerical identification for the measuring point
Number of the turbine meter
CRC of metrological parameters EEprom
Date of battery exchange
Remaining capacity of the battery
0
1
Operating hours
Meter size (G .. )
Shows the date of the last battery replacement
Modbus
Protec-
Data
access
tion
type
A
R
float
N
W
menü16
N
W
menü16
N
W
float
N
W
float
N
W
float
N
W
float
N
W
float
N
W
float
W
N
string8
No (default)
Yes
Min. Max.
Default Unit
-
-
-
0
4
0
0
7
0
-
-
0.0
-
-
1000.0
0.0
25.0
12.0
0.0
0.98
0.7
0.0
25.0
4.0
0.0
25.0
20.0
-
-
0000
0000
mA
mA
I-D
mA
mA
SN

Advertisement

Table of Contents
loading