4 Operation
Coor-
Name
dinate
H01
RS-485 Baud rate
H02
RS-485 parameter
H03
RS-485 protocol
68
H04
Modbus ID
H05
Modbus register offset
4.3.3.6
Coordi-
Name
nate
X01
Time
X02
Date
X10
Delete parameter ar-
chive
X11
Parameter archive fill
level
X14
Delete event archive
X15
Event archive fill level
X16,
Measurement archive
mode
X17,
X18,
X19,
X20,
X21,
X22,
X23
Manual TME400-VMF · EN11 · January 22nd, 2024
Modbus
register
709
710
711
712
713
Archive
Description
Direct entry of the current time as described above.
Direct entry of the current date as described above.
0
1
Display value
0
1
Display value
0
1
If measurement archive mode is activated, the following archives are
visible and can be adjusted and deleted as necessary.
Minutes archive
X17 interval
X18 delete
X19 fill level
Day archive
X20 delete
X21 fill level
Month archive
Modbus
Protec-
Data
access
tion
type
N
W
menu16
N
W
menu16
N
W
menu16
N
W
uint16
N
W
uint16
No (default)
Yes
No (default)
Yes
Off
On (default)
0
15 minutes (default)
1
30 minutes
2
60 minutes
0
No (default)
1
Yes
Display value
0
No (default)
1
Yes
Display value
Min. Max.
Default Unit
0
3
3
0
5
0
0
2
1
1
250
1
0
10000
1