RMG TME 400-VM Operating Manual page 40

Hide thumbs Also See for TME 400-VM:
Table of Contents

Advertisement

1 Introduction
The TME 400 is equipped with permanently lubricated bearings up to a nominal
diameter of DN150 as standard. Nominal diameters of DN200 or higher are provided
with an integrated lubricating device. Optionally, the TME 400 can also be equipped
with the "small oil pump" lubricating devices for DN25 to DN150 versions.
The type of lubricating device and the lubricant requirement depend on the nominal
diameter and the pressure level:
36
Nominal
diameter
DN25-DN150 All pressure classes
DN200
DN250
DN250
> DN300
Also observe the notice plate on the housing.
In unfavorable conditions, e.g. with an accumulation of water and hydrocarbon con-
densate, as well as dust-laden gases, more frequent lubrication is recommended,
even daily in extreme cases (e.g. with continuous condensate formation).
Note
Recommended lubricating oil:
Shell Tellus S2 MA 10 or another oil with 2 to 4°E at 25°C.
Manual TME400-VMF · EN11 · January 22nd, 2024
Pressure classes Lubricating device
As necessary (see below) optional
small oil pump
(push-button operated)
All pressure classes
Small oil pump
PN10 to PN16
(push-button operated)
ANSI 150
PN25 to PN100
Large oil pump
ANSI300 toANSI600
(lever operated)
All pressure classes
Lubricant require-
ment
Every 3 months
6 strokes
Every 3 months
6 strokes
Every 3 months
2 strokes