3.6.7 VERIFY RAM FROM SERIAL PORT
Use the following front panel keyboard procedure to verify
that the RAM data is the same as the incoming serial port
data:
1. Set-up the seriai port. Refer to section 2.
2.
Select the appropriate data transiation format from
appendix A and execute the format select function
83
(see subsection
3.8).
3.F?,
8
to select the mode.
298
Displays
( VE
RI F
~
1
TI R
TR
FR
OM)
4.~~
~
to select the source of the data.
298
Displays
r
1
i-i i-i
!iii
n
11
n
i-i /
~
T /
r-
. J-P',
>-f
.1
I
..
I"-.!
I I
I I
l"r'
A
~.,
I
.4
t-
\ r
r
II
I ' ' I
I
..LJ ..LJ
I ' '
_, .....
~
' -
rn1
I
I
II
.
' - ' )
The prompt
(A.)
preceding "ADDR" in the display
means that you can change the begin RAM address to
any address within the range of RAM word limit by
entering the address hex value with the keyboard. If an
entry is not made, the value defaults to the first
incoming address. If a hex value appears in place of
"ADDR," it is from a previously entered begin address.
a. If the hex value that appears in place of "ADDR" is
correct, go to step 5.
b. If it is incorrect, enter the correct hex value.
c. If you do not wish to change the begin device
address or block size {step 5), go to step 6.
5.E?i
G
298 Displays
The prompt
(.A. )
preceding "SIZE" means that you can
change the block size by entering the hex value with the
keyboard.
if
an entry is not made, the value defaults to
RAM size minus the begin RAM address. If a hex value
appears in place of "SIZE," it is from a previously
entered block size.
a.
!f
the hex value that appears in place of "SIZE" is
correct, go to step
6.
b. If it is incorrect, enter the correct hex value, then go
to step
6.
s.E??i
~l
I(
PORT
II
bdJ
to select the destination for the data.
298
Displays
The prompt
(A. )
preceding "ADDR" means that you
can change the address offset by entering the hex value
with the keyboard. If an entry is not made, the value
defaults to zero (0). If
a
hex value appears in place of
"ADDR," it is from a previously entered address offset.
a.
If
the hex value that appears in place of "ADDR" is
correct, go to step
7.
b. If it is incorrect, enter the correct hex value, then go
to step
7.
~
7 . 1 1
298
Displays
PORT
B)
NOTE
The amount of time the programmer will
require to perform this operation will vary
depending on the data format, block size,
and baud rate. The action symbol
character rotates while the operation is
taking place.
8. When the operation is complete, the following display
signals the programmer's readiness. If an error code is
displayed, see appendix E.
NOTE
HHHH is the hex sumcheck of all the
device data. If block limits are set the
sumcheck (HHHHJ will be calculated oniy
for the block size.
9. To repeat the verify operation, return to step 7.