Table E-1. Error Codes (Continued)
DISPLAY
DESCRIPTION
.
CORRECTIVE ACTION
BLOCK MOVE ERR 97
Block Move was attempted outside RAM
Redefine parameters.
boundaries.
DEV EXCEEDED
98
Programming data exceeded the last device
Redefine parameters.
address.
ERRORS
AID thru A9
These are pak-related errors. Refer to your
Refer to your programming pak manual.
programming pak manual.
110 FORM ERR
93
The number of input records did not equal
Check the connection of all units in the system,
the Record Count (MOS Technology format
data format, and data source, and then try
only).
again.)
BAD REC TYPE
94
The record type was in error. (Intel-
Check the connection of all units in the system,
lntellec 8/MDS, Intel MCS-86 and T.I.
data format, and data source, and then try
SDSMAC formats only.)
again.
ERROR
96*
Illegal center point for RAM shuffle.
Check parameters and re-enter.
*Remote Control only; will not occur during front panel operation, hence no front panel display.
E-5
10-990-0013
Need help?
Do you have a question about the 298 and is the answer not in the manual?
Questions and answers