3) Hook up the hole [1] of the left media take-up unit with the protrusion [2] of the left media take-up unit mounting bracket, and hook up the hole [3] of the right
media take-up unit with the protrusion [4] on the right media take-up unit mounting bracket. Secure the media take-up units firmly by using three M4 hex screws
[5] on each side.
4) Place the media take-up sensor unit under the bottom stand stay, than pull up the cord of the media take-up sensor unit through the hole of the right stand leg.
3-12
[2]
[1]
[5]
F-3-20
F-3-21
[3]
[4]
[5]