Chapter 4 Sync Master/Slave - Banner LTF12 Instruction Manual

Time of flight laser distance sensor with io-link
Hide thumbs Also See for LTF12:
Table of Contents

Advertisement

 
LTF Time Of Flight Laser Distance Sensor With IO-Link Instruction Manual 
Chapter Contents
 
Chapter 4
 Two LTF sensors may be used together in a single sensing application. To eliminate crosstalk between the two sensors, con-
figure one sensor to be the master and one to be the slave. In this mode, the sensors alternate taking measurements and the
response speed triples.
Configure the first sensor as the master; navigate: MENU › INPUT › Type › SyncMstr. 
1.
Configure the second sensor as the slave; navigate: MENU › INPUT › Type › SyncSlve. 
2.
Connect the gray (input) wires of the two sensors together. 
3.
June 22, 2023
 Sync Master/Slave 
© Banner Engineering Corp.
 