7.11.2. Initiating a Software Upgrade

Utilities
Upgrade
Yes
Cancel

7.11.3. Restoring the CEM to its Factory Default Configuration

Utilities
Factory reset
Yes
Cancel

7.12. CLEAR FAULTS AND PEAKS

Clear faults and peaks
Clear,
Cancel
Gray background indicate un-implemented or un-tested features
7735CEM Composite Encoder with Monitoring
This menu item is used to initiate an upgrade of the module software.
In addition to the software upgrade support detailed in this manual (See the
Upgrading Firmware section of this manual for more information), you can
initiate an upgrade with this command. This will allow you to upgrade the
software without unplugging the card and changing the upgrade jumper.
After selecting the upgrade operation, you must change the command to
Yes and press the pushbutton before the upgrade can take place. You can
abort the operation by pressing the pushbutton when Cancel is displayed.
After the upgrade has finished, the unit will automatically restart and run in
normal operating mode.
This menu item is used to restore all controls back to their factory defaults.
After selecting the reset operation, you must change the command to Yes
and press the pushbutton before the command takes place. After the
command, all parameters will be set to their factory default. You can abort
the operation by pressing the pushbutton when Cancel is displayed.
This menu item on the top level menu provides a convenient method to
clear any fault conditions and reset audio peak holds.
perform the clear by pressing the toggle switch up or down when not in the
menu structure or use a GPI if it is programmed to do so.